Improve water retention, smooth application and open time for better finishing performance.
Enhance adhesion, flexibility and crack resistance in cement-based wall formulations.
Improve anti-sagging performance and application consistency for smoother construction.
Wall putty is applied in layers of 1–3 mm, so it dries faster and is judged more harshly than any other mortar: powdering, hairline cracks and trowel drag are visible the next morning. The fix is almost never more cement — it is the right cellulose ether grade for the layer thickness, enough polymer to bind the surface, and a starch ether to make the putty move under the blade. This page gives the grades and starting dosages for cement-based, gypsum-based and exterior putties.
| System | Binder | Where it is used | What the additive package must do | Reference standard |
|---|---|---|---|---|
| Cement-based skim coat / exterior putty | White or grey cement + limestone filler | Exterior façades, wet rooms, concrete leveling before paint | Water retention on absorbent substrates, adhesion to concrete and AAC, water resistance, crack control | EN 998-1 (OC/GP render types) |
| Gypsum-based finishing putty | Gypsum hemihydrate (± lime) | Interior walls and ceilings, plasterboard joints and skim | Open time control, sandability, no shrinkage cracking, smooth white surface | EN 13279-1 (C6 thin-coat, C7 finishing plaster) |
| Polymer-modified interior putty | Cement or gypsum with 3–8 % RDP | High-end interior finishing, machine-applied skim | Zero powdering, flexibility over joints, fine texture | EN 998-1 / EN 13279-1 as applicable |
Landercoll® cellulose ether. The technical data sheets list “skim coat / wall putty (powder form)” for K75, K100, EM60, EM80 and EM100, “skim coat / wall putty” for K150, K200, K200H and EM200, and “wall putty / skim coat” for EM100H. For ready-mixed paste putty the TDS recommends the surface-treated, delayed-solubility grades K40HS and K75HS (“latex-based and paste application, wall putties, joint fillers”). For gypsum putty the dedicated HEMC grades are ME3570-G and ME4080-G (“gypsum-based wall putty / skim coat”). Viscosities are Brookfield RV, 2 % solution, 20 °C.
| Putty type | Cellulose ether (viscosity) | Starting dosage | Notes |
|---|---|---|---|
| Interior cement putty, hand-applied, 1–2 mm | K75 (35,000–40,000) · K100 (45,000–60,000) / EM80 (35,000–45,000) · EM100 (45,000–60,000) | 0.25–0.35 % | Standard putty grades on the TDS; K200 (65,000–80,000) for very absorbent blockwork |
| Exterior cement putty, 2–3 mm | K150 (55,000–65,000) · K200H / EM100H (45,000–60,000) | 0.30–0.40 % | K150: water retention “very high”; EM100H: sag resistance “excellent”, heat resistance “excellent” |
| Machine-sprayed skim coat | EM60 (30,000–40,000) · EM80 / K75 | 0.25–0.35 % | Medium viscosity for pumpability; combine with ST2109 or ST3152 starch ether for anti-sag |
| Gypsum finishing putty | ME3570-G (35,000–45,000) · ME4080-G (30,000–40,000) | 0.15–0.30 % | HEMC modified for gypsum: water retention “excellent”, final consistency “superior”; K100 / EM100 also list gypsum plasters |
| Ready-mixed (paste) putty | K40HS (20,000–24,000) · K75HS (35,000–40,000) | 0.3–0.5 % | Surface-treated for delayed dissolution and lump-free mixing in water; combine with Landercoll® HEC for storage stability |
Accurate® redispersible polymer powder
| Grade family | Grades (TDS Tg / MFFT) | Typical dosage | Use |
|---|---|---|---|
| Rigid VAE | 5011N, 4012N (Tg 10 ± 5 °C / MFFT 4 °C) | 1–2 % | Interior putty: hardness, no powdering, good sandability — both TDS list wall putty |
| Semi-flexible VAE | 4025N (Tg 0 °C / MFFT 1 °C) | 2–3 % | Exterior putty on render, cement board, AAC |
| Flexible | 5045N (Tg −10 ± 5 °C / MFFT 0 °C), 9055E acrylic–silane (Tg −15 °C) | 3–5 % | Putty over ETICS base coats and substrates with movement; 5045N TDS lists wall putty / skim coat, 9028E/9055E list thermal-insulation putty systems |
| Hydrophobic | 8032H (medium hydrophobic), 8035H (strong hydrophobic), 8048H (very strong, instant-dissolving) | 2–4 % | Wet rooms and façades exposed to driving rain; 8032H and 8035H TDS list skim coat, 8048H lists waterproof putty |
NOVASTAR® specialty additives
Dosages are percentages of the total dry mix for laboratory starting points; the technical data sheets do not prescribe dosages. Confirm with your binder and filler.
| Defect | What is happening | Formulation fix |
|---|---|---|
| Powdering / chalking after drying | Water left the layer before the binder hydrated; too little polymer at the surface | Raise cellulose ether by 0.05 % or move to K150 / EM100H; add 1–2 % rigid RDP (5011N); check filler/binder ratio |
| Hairline map cracking | Thick single coat, fast drying, high filler content | Limit coat to ≤ 2 mm per pass; K150 or EM100H for water retention; 2–3 % 4025N; add 0.1 % PP fibre 3 mm for exterior |
| Sagging on walls, slumping in the bucket | Viscosity too low for layer thickness; excess water | EM100H or K200 (sag resistance “excellent”); 0.05 % ST1506-A; reduce water |
| Putty “rolls” or drags under the trowel | Cellulose ether viscosity too high; no starch ether | Step down one viscosity (K200 → K100 → K75); add ST1506-B or ST3547 |
| Hard to sand | Too much RDP or flexible RDP in an interior putty | Reduce to 1–2 % rigid RDP (5011N / 4012N) |
| Pinholes, bubbles | Air entrained during high-speed mixing or spraying | 0.1–0.2 % P805 (P806 in high-alkali cement putty); slower mixer |
| Lumps when mixing paste putty | Standard cellulose ether dissolves on contact and agglomerates | Surface-treated K40HS / K75HS (delayed solubility: “yes” on the TDS) |
| Yellow or dark spots in white putty | Cement or filler impurities, not the additive | Change to white cement / low-iron limestone; cellulose ether and RDP are white to off-white powders |
| Blistering or peeling on exterior putty | Water uptake and freeze; weak bond to render | SHP 0.3 %; hydrophobic RDP 8035H or 8048H; prime absorbent substrate |
| Short working time of gypsum putty | Set not controlled | Gypsum retarder P300 at 0.05 % or P400 at 0.03 %; ME3570-G cellulose ether |
Our field guide Why wall putty fails on site and the test-based article Wall putty powdering after drying go deeper into each case.
Formulators often ask whether a powdering putty needs more cellulose ether or more polymer. The quick test: wet the powdered surface. If it re-hardens, the cement never hydrated — add water retention. If it stays soft, the binder is fine but the surface is unbound — add RDP. The full comparison is in HPMC vs RDP in wall putty.
| Component | Interior cement putty | Exterior cement putty | Gypsum finishing putty |
|---|---|---|---|
| White cement 42.5 | 25–30 % | 30–35 % | — |
| Gypsum hemihydrate | — | — | 60–70 % |
| Limestone / heavy calcium carbonate | 60–70 % | 55–60 % | 25–35 % |
| Light calcium carbonate / talc | 3–5 % | 3–5 % | 3–5 % |
| Landercoll® cellulose ether | K100 0.30 % | EM100H 0.35 % | ME3570-G 0.20 % |
| Accurate® RDP | 5011N 1.5 % | 4025N 2.5 % | 5011N 0.5–1 % |
| NOVASTAR® starch ether | ST1506-B 0.05 % | ST3547 0.05 % | ST1506-A 0.03 % |
| NOVASTAR® SHP75 / SHP80 | — | 0.3 % | — |
| NOVASTAR® gypsum retarder P400 | — | — | 0.02–0.05 % |
These are starting points used in our application laboratory, not finished recipes; raw-material sources and local standards require adjustment and testing.
LANDU has produced cellulose ethers since 2011 and today runs three production bases in Shandong with 75,000 t annual capacity across Landercoll® cellulose ethers, Accurate® RDP and NOVASTAR® additives. The portfolio is REACH-compliant and manufactured under ISO 9001. Putty manufacturers in more than 60 countries use our grades; in Europe we deliver from stock through partners in several countries, including Greece, Spain and Italy. Cellulose ether ships in 25 kg bags on 500 or 600 kg pallets, RDP in 25 kg bags on 600–1,300 kg pallets (neutral or OEM bags available), with a lead time of 7–15 working days for factory shipments.
For hand-applied interior putty, 45,000–60,000 mPa·s Brookfield (Landercoll® K100 / EM100; 85,000–110,000 mPa·s on the NDJ-1 scale) at 0.25–0.35 % is the usual starting point. Machine-sprayed skim coats work better with 30,000–45,000 mPa·s grades (EM60, EM80, K75); very absorbent blockwork may need K200.
Interior putty: 1–2 % of a rigid grade (5011N or 4012N) to stop powdering while keeping sandability. Exterior putty: 2–3 % semi-flexible 4025N, rising to 3–5 % flexible 5045N or 9055E over insulation systems. Above 5 % the putty becomes difficult to sand and the cost rises quickly.
No. Gypsum sets by crystallisation and is sensitive to cellulose ether type and dosage; use the gypsum HEMC grades ME3570-G or ME4080-G at 0.15–0.30 % plus a retarder. Cement putty tolerates higher cellulose ether dosages and benefits more from RDP.
Sun, wind and absorbent render remove water three to five times faster outdoors. Move from K100 to K150 or EM100H, add 0.05 % starch ether to allow a thinner coat, and raise RDP to 2.5–3 % to carry shrinkage stress.
Not necessary, but 0.03–0.08 % of a putty grade such as ST1506-B or ST3547 changes the trowel feel noticeably: less drag, better anti-sag, and usually 1–2 % less water, which in turn reduces shrinkage.
Yes. Landercoll® grades are white to off-white powders with residue on ignition ≤ 5 % (EM100H ≤ 3 %); Accurate® RDP is white to light beige. Colour problems in finished putty almost always come from grey cement or iron-bearing filler.
Three jobs. It holds the mixing water in a 1–3 mm layer on an absorbent wall long enough for the cement to hydrate, which is what stops powdering. It sets the consistency so the putty moves under the blade without dragging. And it gives the yield stress that keeps a 2–3 mm coat on a vertical surface. Starting dosage 0.25–0.35 % of the dry mix; the grades whose TDS list putty are Landercoll® K75, K100, K150 and K200 and the HEMC grades EM60, EM80, EM100, EM100H and EM200.
At room temperature they retain water and thicken in the same way. HEMC (MHEC) has a higher thermal gel point, so it keeps its viscosity and open time in hot workshops and on sun-warmed walls above about 30 ℃, and at equal viscosity it usually gives a slightly smoother trowel feel. HPMC is the lower-cost choice for interior putty applied in temperate conditions. Run K100 and EM100 in the same base mix and compare water retention, sag and sanding; the TDS pairs for putty are K75 / EM80 and K100 / EM100.
Powdering means the surface cement never hydrated: the wall pulled the water out before set, or there was too little binder to coat the filler. Check in this order: water retention (raise the cellulose ether to 0.30–0.35 %, or move from K75 to K100), binder-to-filler ratio, RDP (1–2 % rigid 5011N or 4012N binds the surface), then curing conditions (wind, direct sun, heated rooms). More cellulose ether does not rescue a mix that is short of binder. The full test sequence is in wall putty powdering after drying.
We return a grade recommendation and starting dosage within two working days and ship 200–600 g samples free of charge.
LANDU — Committed to Every Gram.