Cement Render & Plaster Additives for Hand- and Machine-Applied Mortars

Water retention, workability and crack control for hand-applied and machine render.

  • Improved water retention
  • Better workability
  • Enhanced anti-sag performance
  • Longer open time
  • Smoother application consistency
  • Easy mixing and application
  • Improved troweling performance
  • Stable thickening effect
  • Better moisture retention
  • Consistent mortar quality
  • Improved bonding strength
  • Better crack resistance
  • Enhanced flexibility
  • Improved impact resistance
  • Reduced dusting and surface brittleness

LANDU: Your Cement Render & Plaster Additives Manufacturer

Render is applied thick, fast and often by machine, onto substrates that range from dense concrete to thirsty aerated blocks. The additive package has to keep 10–20 mm of mortar workable on the wall, hold water against the suction of the substrate, and still let the surface be floated an hour later. This page sets out the Landercoll®, Accurate® and NOVASTAR® grades for each render type under EN 998-1, with starting dosages and a troubleshooting section for the problems site crews report: sagging, map cracking, pump blockage and efflorescence.

Render types under EN 998-1 and what they need from additives

EN 998-1 typeDescriptionDeclared properties that additives influenceAdditive priorities
GP – general purposeBase and finishing coats, interior and exteriorCompressive strength class CS I–IV, adhesion, capillary absorption W0–W2Water retention, workability, sag resistance
LW – lightweightDensity ≤ 1,300 kg/m³, insulatingAdhesion to lightweight aggregate, crack controlHigh water retention, fibre, polymer
OC – one-coatSingle 15–20 mm coat, often coloured, exteriorWater permeability after climatic cycles, adhesionHydrophobicity, water retention, crack resistance
R – renovationOver salt-laden masonryHigh porosity, water-vapour permeability, salt resistanceAir content control, water retention, no film-forming sealants
T – thermal insulatingλ ≤ 0.2 W/m·KAdhesion, shrinkage controlPolymer, fibre, water retention

Grade selection

Landercoll® cellulose ether. The technical data sheets list “cement base plasters/renders” for HPMC K75 and K100 and for HEMC EM60, EM80 and EM100, and “plaster/render” for the highly modified EM100H. For render, HEMC is often preferred: every EM data sheet rates heat resistance “excellent” (HPMC: “standard”), which keeps water retention stable in warm mixing water and long pump lines. Viscosities are Brookfield RV, 2 % solution, 20 °C; NDJ-1 readings are about twice as high.

RenderCellulose ether (viscosity)Starting dosageComment
Hand-applied base coat, 10–15 mmK100 (45,000–60,000) / EM100 (45,000–60,000)0.12–0.20 %Highest render-grade viscosity for body on the wall at low dosage
Machine-sprayed renderEM60 (30,000–40,000) · EM80 (35,000–45,000) / K75 (35,000–40,000)0.15–0.25 %Medium viscosity passes the pump; combine with ST2109 or ST3152 starch ether
Finishing render / float coat, 3–5 mmK75 / EM600.15–0.20 %Easier floating, longer open time
One-coat (OC) exterior renderEM100H (45,000–60,000)0.20–0.30 %Water retention “high” and sag resistance “excellent” for hot façades
Lightweight / thermal renderEM100H / K1000.20–0.30 %Holds light aggregate in suspension at the upper dosage
Renovation renderEM80 / EM1000.15–0.20 %Combine with air entrainer, no hydrophobic film

Accurate® redispersible polymer powder — not every render needs polymer; use it where adhesion or flexibility is declared. All four grades below list renders or plasters on their technical data sheets.

RenderGrade (TDS Tg / MFFT)Dosage
Base coat on concrete, AAC, mixed substratesRigid 4012N or 5011N (Tg 10 ± 5 °C / 4 °C)1–2 %
Exterior OC render, high-stress areas (plinths, parapets)Semi-flexible 4025N (Tg 0 °C / 1 °C)2–3 %
Render over insulation or old renderFlexible 5045N (Tg −10 ± 5 °C / 0 °C)3–4 %
Water-repellent render (W2)Strong hydrophobic 8035H (TDS: mineral renders & plasters; Tg −10 ± 5 °C / 0 °C)2–3 %

NOVASTAR® specialty additives

  • Starch ether, 0.02–0.06 %: ST2109 (5 % viscosity 1,000–5,000 mPa·s; TDS: machine-applied mortars, excellent anti-sag) and ST3152 (1,000–6,000 mPa·s, residue on ignition ≤ 3 %, neutral pH; TDS: machine-applied mortars, good thixotropy) give the “stiff on the wall, fluid in the hose” behaviour; ST1506-A (500–3,500 mPa·s) is the hand-applied plaster grade.
  • SHP75 / SHP80 silicone hydrophobic powder, 0.2–0.5 % (TDS range 0.1–0.5 %): capillary absorption class W2 (c ≤ 0.2 kg/m²·min^0.5) and efflorescence control; the TDS names mortar, stucco and façade render as applications.
  • PP fibre 6–12 mm, 0.05–0.15 %: plastic-shrinkage crack control, especially in OC and lightweight renders.
  • Powder defoamer P805, 0.1–0.2 % (P806 alkali-resistant for lime-rich renders, P807 low-temperature): control of air content when an air entrainer is also used.
  • Air-entraining agent (third-party): 12–20 % air for workability and freeze–thaw in exterior render; keep below 20 % to protect strength.

Dosages are percentages of the total dry mix as laboratory starting points; the technical data sheets do not prescribe dosages.

Troubleshooting

SymptomLikely causeAdjustment
Render sags or slumps on the wall at 15 mmViscosity too low; too much water; no thixotropyEM100H (sag resistance “excellent”); 0.03 % ST2109; reduce water 1 %
Map cracking within 24 hPlastic shrinkage from fast water lossEM100H for water retention; 0.1 % PP fibre; protect from sun and wind
Later shrinkage cracks, 1–4 weeksToo much binder or water; no flexibilityLower cement content, add 2–3 % 4025N, cure
Hollow sound, debonding from concreteDense substrate, no key, no polymerSpatterdash or bonding coat; 2 % 5011N; wet the substrate
Debonding from AAC blocksSubstrate sucked the waterK100 / EM100 at 0.20 %; pre-wet or prime the blocks
Pump blockage, surgingWater retention collapses under pressure; airEM80 / EM100 (heat resistance “excellent”); ST3152; P805 defoamer; constant water dosing
Dusting, weak surfaceWater retention too low; over-floatingRaise cellulose ether 0.03 %; 1 % 4012N
Efflorescence, white bloomWater migration carrying lime and saltsSHP 0.3 %; hydrophobic 8035H; low-alkali cement
Render stays damp, algaeCapillary uptakeSHP 0.3–0.5 %; W2 class design

Related reading: Machine-applied render: pump blockage and sagging · Water retention in dry-mix mortar · Crack resistance in dry-mix mortar.

Hand vs machine application: what changes

FactorHand-appliedMachine-sprayed
ViscosityHigh (K100 / EM100) for body on the trowelMedium (K75 / EM60–EM80) to pass the pump and hose
Water retentionImportant on absorbent substratesCritical — pressure and shear squeeze water out of the mortar
ThixotropyHelpful (ST1506-A)Essential: ST2109 or ST3152 at 0.02–0.06 % so the mortar stiffens on impact with the wall
Air content8–15 %12–20 %, controlled with defoamer to avoid strength loss
Cellulose ether typeHPMC or HEMCHEMC preferred: heat resistance “excellent” on the TDS, lubrication in the hose

Starting formulations (dry mix, laboratory basis)

ComponentMachine-sprayed base renderOne-coat exterior render (OC)
CEM II/B 32.5 or 42.518–22 %20–24 %
Hydrated lime3–5 %2–4 %
Sand 0–2 mm70–75 %65–70 %
Limestone filler / lightweight filler3–5 %5–8 %
Landercoll® HEMCEM80 0.18 %EM100H 0.25 %
NOVASTAR® starch etherST3152 0.03 %ST2109 0.03 %
Accurate® RDP—4025N 2 %
NOVASTAR® SHP75 / SHP80—0.3 %
PP fibre 6 mm—0.1 %
Air-entraining agent0.01–0.03 %0.01–0.03 %
Pigment—as required

Starting points only; adjust to local sand grading and the declared EN 998-1 class.

Supply

Render is a high-volume, low-dosage product, so additive cost per tonne of mortar is small but consistency is everything: a viscosity swing of 15 % in the cellulose ether changes water demand on the pump. LANDU manufactures Landercoll® cellulose ethers in its own three plants in Shandong (75,000 t/year total capacity) under ISO 9001 with batch viscosity certificates, supplies REACH-compliant grades to dry-mortar producers in more than 60 countries, and holds stock with partners in several European countries, including Greece, Spain and Italy. Factory lead time 7–15 working days; 25 kg bags on 500 or 600 kg pallets (10 t per 20′, 22 t per 40′ container); MOQ 1 t for cellulose ether; shelf life two years for K75, K100, EM80 and EM100.

Cement Render & Plaster Additives: Frequently Asked Questions

Answers on additive selection, testing, samples and supplier qualification.

Which cellulose ether dosage for a machine-applied cement render?

Start at 0.18–0.20 % of the dry mix with Landercoll® EM80 (HEMC) or K75, plus 0.03 % ST3152 starch ether. Adjust in 0.02 % steps: too little shows as pump surging and dusting, too much as a sticky surface that is hard to float.

Do cement renders need RDP?

Not always. Interior and standard exterior base coats on brick rarely need polymer. Add 1–2 % rigid 4012N or 5011N on dense concrete or AAC, 2–3 % semi-flexible 4025N for one-coat and high-stress zones, and 3–4 % flexible 5045N when rendering over insulation or old render.

How do I reach capillary absorption class W2?

0.2–0.5 % NOVASTAR® SHP silicone hydrophobic powder, optionally with the strongly hydrophobic RDP 8035H, gives c ≤ 0.2 kg/m²·min^0.5 in most GP and OC renders while keeping the render vapour-open.

HPMC or HEMC for render?

Either works; HEMC (Landercoll® EM60, EM80, EM100, EM100H) is usually chosen for machine application and hot climates because the TDS rates its heat resistance "excellent" and it lubricates the hose better. HPMC (K75, K100) is the cost-effective choice for hand-applied interior render.

Why does my render crack on aerated concrete but not on brick?

AAC absorbs water much faster, so the render dries from the back before it hydrates. Move to EM100H at 0.20–0.25 % (water retention "high"), pre-wet or prime the blocks, and add 0.1 % PP fibre.

Can you supply additives for coloured one-coat renders?

Yes. Landercoll® cellulose ethers and Accurate® RDP are white to off-white powders and do not affect pigment shade; SHP reduces the water movement that causes colour patchiness and efflorescence on coloured OC renders.

Request Samples and a Grade Recommendation

Tell us the render type, application method and substrate.

We return a grade recommendation and starting dosage within two working days and ship samples free of charge.

LANDU Company

Ask a Formulation Engineer

LANDU — Committed to Every Gram.