Repair Mortar Additives for Structural and Cosmetic Concrete Repair

Bond, sag resistance and low water demand for EN 1504-3 R1–R4 repair mortars.

LANDU: Your Repair Mortar Additives Manufacturer

A repair mortar has to bond to old concrete that is denser, drier and stiffer than itself, follow the structure’s movement without debonding, and — for structural classes — reach 45 MPa with almost no shrinkage. No single additive does this. Polymer powder provides bond and ductility, cellulose ether gives the thixotropy that holds 30 mm overhead, a polycarboxylate brings the water/cement ratio down to structural levels, fibre and a defoamer control cracking and density. This page sets out the Accurate®, Landercoll® and NOVASTAR® grades for each EN 1504-3 class with starting dosages, a troubleshooting table and a laboratory starting formulation.

EN 1504-3 classes and what they demand from the additive package

ClassUseCompressive strength (28 d)Adhesion (EN 1542)Other key requirementsAdditive priorities
R1Non-structural cosmetic repair, reprofiling≥ 10 MPa≥ 0.8 N/mm²Workability, sag resistanceCellulose ether, 2–3 % RDP
R2Non-structural, thicker cosmetic repair≥ 15 MPa≥ 0.8 N/mm²Crack control, adhesion after thermal cyclingCellulose ether, 3–4 % RDP, fibre
R3Structural repair, moderate loads≥ 25 MPa≥ 1.5 N/mm²E-modulus ≥ 15 GPa, restrained shrinkage/expansion ≥ 1.5 N/mm², chloride ≤ 0.05 %Low w/c via PCE, 2–3 % RDP, fibre, defoamer
R4Structural repair, high loads, carbonation barrier≥ 45 MPa≥ 2.0 N/mm²E-modulus ≥ 20 GPa, capillary absorption ≤ 0.5 kg/m²·h^0.5, carbonation resistancePCE 540P / 590P, silica fume, 1–2 % RDP, fibre, defoamer, shrinkage control

Grade selection by class

AdditiveGrades (TDS data)R1 / R2 cosmetic, hand-appliedR3 structural, trowel or sprayR4 structural, high strength
Accurate® RDP5045N flexible (Tg −10 ± 5 °C; TDS lists repair mortar); 5011N rigid (Tg 10 ± 5 °C); 8048H very strong hydrophobic, instant-dissolving (TDS lists repair mortar); 9028E (Tg 5 °C) / 9055E (Tg −15 °C) acrylic–silane (TDS: repair mortars)5045N 3–4 % (ductility, bond on old concrete)5011N or 8048H 2–3 %5011N 1–2 % (bond, chloride barrier)
Landercoll® cellulose etherK100 / EM100 (45,000–60,000 mPa·s Brookfield; TDS: repair mortar); K75 / EM80 (35,000–45,000); EM40HT (18,000–23,000; TDS: repair mortar, heat resistance “excellent”); K04 (300–500; self-leveling grade)K100 / EM100 0.20–0.30 % (thixotropy for vertical and overhead)EM40HT 0.08–0.15 %K04 0.03–0.06 % (cohesion only)
NOVASTAR® PCE, 530P–580P series (product-page data)540P (sulfoaluminate-cement water reducer, water-reduction rate 34 %) recommended for rapid repair and pavement repair mortar; 530P and 580P compatible—540P or 530P 0.15–0.30 %540P or 580P 0.30–0.50 %
NOVASTAR® PCE (TDS series)590P high water reduction (≥ 25 %, 97 % solids, chloride ≤ 0.02 %); 600P slump retention; 590FP early strength (12 h strength ratio > 240 %). TDS dosage 0.1–0.5 % of cementitious material—590P 0.15–0.30 %590P 0.30–0.50 % (600P share for hot weather, 590FP for rapid return to service)
NOVASTAR® powder defoamerP805 standard; P806 alkali-resistant; P807 low-temperatureP805 0.1 %0.1–0.2 %0.2–0.3 %
NOVASTAR® starch etherST3152 (machine-applied mortars: thixotropy, anti-sag; residue on ignition ≤ 3 %); ST1506-A (hand-applied)ST1506-A 0.03–0.05 % (overhead work)ST3152 0.02–0.05 % (sprayed repair)—
PP fibre6–12 mm monofilament0.1 %0.1–0.15 %0.1–0.15 %
NOVASTAR® SHPSHP75 / SHP80 (TDS dosage 0.1–0.5 %)0.2–0.3 % for exposed façades——
Third-party componentsSilica fume, shrinkage-reducing admixture, expansive agent, calcium formate—silica fume 3–5 %silica fume 5–8 %, SRA, expander

Dosages are percentages of the total dry mix for laboratory starting points; the technical data sheets do not prescribe mortar dosages. In R3/R4 mortars the cellulose ether dosage falls sharply because strength, not sag, is the limiting property.

The role of each additive in a repair

  • Accurate® RDP — the mortar’s bond to old concrete depends on wetting a dense substrate and on a flexible interface that absorbs the mismatch in E-modulus and shrinkage between new and old material. Flexible 5045N (Tg −10 ± 5 °C, MFFT 0 °C) is used in cosmetic repairs where ductility matters most; rigid 5011N (Tg 10 ± 5 °C) in structural classes where E-modulus must stay high; 8048H where chloride and water ingress are the reason for the repair — its TDS lists repair mortar, waterproof mortar and a very strong hydrophobic effect; the acrylic–silane 9028E / 9055E where weather resistance and freeze–thaw performance are specified.
  • Landercoll® HPMC / MHEC — gives the thixotropy that lets 20–30 mm hold on a soffit, and the water retention that stops the old concrete sucking the repair dry. K100 / EM100 for hand-applied cosmetic repair; EM40HT (water retention “excellent”, heat resistance “excellent”) for structural trowel and sprayed mortars; only K04 for high-strength R4.
  • NOVASTAR® PCE 540P — the recommended grade for rapid-repair mortar in our 530P–580P series (sulfoaluminate-cement water reducer, 34 %); 530P and 580P are compatible alternatives.
  • NOVASTAR® PCE 590P (TDS series) — brings the water/cement ratio to 0.35–0.40 so that R3/R4 strength and low permeability are reached without excess water; 600P is blended in when hot weather shortens the placement window, 590FP when the structure has to return to service quickly.
  • NOVASTAR® defoamer P805 — removes the air that polymer and spraying entrain; as a rule of thumb every 1 % of air costs roughly 5 % of compressive strength. P806 for alkali-rich, cement-heavy mixes; P807 for winter repairs.
  • PP fibre — controls plastic-shrinkage cracking in large patches and sprayed layers; 6 mm for trowel mortars, 12 mm for sprayed.
  • Starch ether ST3152 — fine-tunes anti-sag and pumpability in wet-sprayed repair mortars without adding more cellulose ether.

Cause-by-cause diagnosis of bond failures, with pull-off test procedure, is in Repair mortar bond failure diagnosis.

Troubleshooting

SymptomLikely causeAdjustment
Pull-off < 1.5 N/mm² with failure at the interfaceDry, dusty or laitance-covered substrate; low polymerPrepare to CSP 3–5 and pre-wet to SSD; RDP ≥ 3 %; scrub first layer in
Hollow sound after 7 daysShrinkage pulled the patch awayLower w/c with 590P; fibre 0.1 %; SRA; cure 3–7 days wet
Sags or falls off overhead at 20 mmInsufficient thixotropyK100 / EM100 0.25 %; ST1506-A 0.03 %; apply in 10–15 mm passes
Cracks across the patch in 24 hPlastic shrinkage in sun/windFibre 0.1 %; cellulose ether +0.05 %; protect and cure
Low 28-day strength for R4w/c too high; air590P 0.4 %; P805 0.25 %; silica fume; check water dosing on site
Pinholes, low density, high permeabilityAir from polymer and mixingP805 0.2–0.3 %; slower mixing
Mortar sticks to the trowel, dragsCellulose ether too high; polymer too flexible for the classReduce to EM40HT 0.10 %; move to 5011N
Rebound and blockages in wet sprayingRheology not matched to the pumpST3152 0.03 %; EM40HT; P805; constant water
Working time too short in summerFast slump lossReplace part of 590P with 600P (slump retention)
Efflorescence on façade repairsWater movementSHP 0.3 %; hydrophobic RDP 8048H

Starting formulations (dry mix, laboratory basis)

ComponentR2 cosmetic repair mortarR4 structural repair mortar
CEM I 42.5 R / 52.5 R30–35 %38–42 %
Silica fume—5–6 %
Quartz sand 0–1 mm / 0–2 mm55–60 %45–50 %
Limestone filler5–8 %3–5 %
Accurate® RDP5045N 3.5 %5011N 1.5 %
Landercoll® cellulose etherK100 0.25 %K04 0.04 %
NOVASTAR® PCE—540P or 590P 0.40 %
NOVASTAR® defoamer P8050.10 %0.25 %
NOVASTAR® starch ether ST1506-A0.03 %—
PP fibre 6 mm0.10 %0.12 %
Calcium formate0.5 %—
Shrinkage-reducing / expansive agent—per supplier
Water≈ 17–19 %≈ 13–15 %

Starting points only; EN 1504-3 testing (strength, adhesion, restrained shrinkage, E-modulus, chloride, carbonation for R4) must be completed on the final blend.

Products referenced on this page

Supply

Repair mortars are specified products: once a formulation has passed EN 1504-3, the additive grades cannot change. LANDU manufactures Landercoll® cellulose ethers, Accurate® polymer powders and NOVASTAR® PCE, defoamers and fibres in its own three plants in Shandong (75,000 t/year) under ISO 9001 with batch certificates, so a grade approved in your lab is the grade delivered for years. The portfolio is REACH-compliant; European stock is held with partners in several countries, including Greece, Spain and Italy; factory lead time 7–15 working days; 25 kg bags on pallets (cellulose ether 500–600 kg, RDP 600–1,300 kg per pallet). Shelf life per TDS: K100 / EM100 two years, RDP one year, PCE powder twelve months.

Repair Mortar Additives: Frequently Asked Questions

Answers on additive selection, testing, samples and supplier qualification.

Which RDP for a structural R3/R4 repair mortar?

A rigid grade — Accurate® 5011N (Tg 10 ± 5 °C) at 1–3 % — so that the E-modulus requirement (≥ 15 / 20 GPa) is met while bond and chloride resistance improve; 8048H where the repair must also be a water and chloride barrier. Flexible 5045N and the acrylic–silane 9028E / 9055E are reserved for R1/R2 cosmetic repairs where ductility matters more than stiffness.

How much cellulose ether does a repair mortar need?

It depends on the class. Hand-applied cosmetic repair needs 0.20–0.30 % of Landercoll® K100 / EM100 for sag resistance; structural trowel mortars 0.08–0.15 % of EM40HT; high-strength R4 only 0.03–0.06 % of the low-viscosity K04 for cohesion. More than that costs strength and bond.

Why is PCE needed in a repair mortar?

R3/R4 strength and the capillary absorption limit of R4 require a water/cement ratio around 0.35–0.40, which cannot be mixed and placed without a superplasticizer. NOVASTAR® 590P (water-reduction rate ≥ 25 % on the TDS) at 0.3–0.5 % provides the water reduction while keeping the mortar workable for 30–45 minutes; blend in 600P for longer placement windows. In rapid-setting and sulfoaluminate repair mortars, 540P is the recommended grade.

Do I need both fibre and RDP?

They do different jobs. Fibre controls plastic-shrinkage cracks in the first 24 hours; RDP provides bond and long-term ductility. Most repair mortars above 10 mm thickness use both.

What substrate preparation do your dosages assume?

Sound concrete roughened to CSP 3–5, free of laitance and dust, pre-wetted to saturated surface-dry with no standing water. With poorer preparation, no additive dosage will reach the EN 1542 adhesion values.

Can LANDU run EN 1504-3 screening tests?

Our laboratory runs compressive and flexural strength, pull-off adhesion on prepared concrete slabs, restrained shrinkage screening, air content and capillary absorption on customer formulations, and recommends grades and dosages for the target class. Full certification testing is carried out by a notified body.

Is LANDU a repair mortar additives manufacturer in China?

Yes. Landercoll® cellulose ethers, Accurate® polymer powders and NOVASTAR® PCE, defoamers and fibres are made in LANDU's own three plants in Shandong Province (75,000 t/a); headquarters and laboratory are in Jinan. Minimum order 1,000 kg per grade in 25 kg bags; stock grades ship in 7–14 days, FOB or CFR/CIF to European ports; free 500 g – 1 kg samples with TDS and batch COA.

Which additives are used in concrete repair mortar?

A cellulose ether for water retention and non-sag consistency (K100 / EM100 at 0.20–0.30 % for hand-applied mortar; EM40HT where heat resistance matters), an RDP for bond to old concrete and ductility (5045N for R1–R3, 8048H or 9055E where water exposure adds to the brief; 5011N where a rigid, economical bond is enough), a PCE for strength at low water (590P, 0.15–0.50 % by class), a powder defoamer, and PP fibre for plastic-shrinkage control. Structural R4 mortars add silica fume and a shrinkage-reducing or expansive component.

Should we use HPMC or MHEC for repair mortar?

Both retain water and build consistency in the same way at moderate temperature. MHEC (HEMC) keeps its viscosity and open time above 30 ℃ and is the grade family the TDS rate "excellent" for heat resistance, so it is the choice for sprayed repair in summer and for hot climates. HPMC is the cost-efficient choice for hand-applied repair in temperate conditions. The grades whose TDS list repair mortar are K75 and K100 (HPMC) and EM40HT, EM60, EM80 and EM100 (HEMC). Test the two side by side on the same substrate before fixing the formulation.

Can LANDU supply an additive certified for EN 1504-3 R3 or R4 repair mortar?

EN 1504-3 classes apply to the finished repair product, not to an individual HPMC, RDP or PCE. What we supply is the additive package and the laboratory screening (compressive strength, pull-off adhesion, restrained shrinkage) that shows whether a formulation is heading for R3 or R4 before you pay for third-party testing. The declaration of performance remains the mortar manufacturer's.

Request Samples and a Grade Recommendation

Tell us the target EN 1504-3 class, application method (trowel, spray) and layer thickness.

We return RDP, cellulose ether, PCE and fibre recommendations with dosages within two working days and ship samples free of charge.

LANDU Company

Ask a Formulation Engineer

LANDU — Committed to Every Gram.