Render is applied thick, fast and often by machine, onto substrates that range from dense concrete to thirsty aerated blocks. The additive package has to keep 10–20 mm of mortar workable on the wall, hold water against the suction of the substrate, and still let the surface be floated an hour later. This page sets out the Landercoll®, Accurate® and NOVASTAR® grades for each render type under EN 998-1, with starting dosages and a troubleshooting section for the problems site crews report: sagging, map cracking, pump blockage and efflorescence.
| EN 998-1 type | Description | Declared properties that additives influence | Additive priorities |
|---|---|---|---|
| GP – general purpose | Base and finishing coats, interior and exterior | Compressive strength class CS I–IV, adhesion, capillary absorption W0–W2 | Water retention, workability, sag resistance |
| LW – lightweight | Density ≤ 1,300 kg/m³, insulating | Adhesion to lightweight aggregate, crack control | High water retention, fibre, polymer |
| OC – one-coat | Single 15–20 mm coat, often coloured, exterior | Water permeability after climatic cycles, adhesion | Hydrophobicity, water retention, crack resistance |
| R – renovation | Over salt-laden masonry | High porosity, water-vapour permeability, salt resistance | Air content control, water retention, no film-forming sealants |
| T – thermal insulating | λ ≤ 0.2 W/m·K | Adhesion, shrinkage control | Polymer, fibre, water retention |
Landercoll® cellulose ether. The technical data sheets list “cement base plasters/renders” for HPMC K75 and K100 and for HEMC EM60, EM80 and EM100, and “plaster/render” for the highly modified EM100H. For render, HEMC is often preferred: every EM data sheet rates heat resistance “excellent” (HPMC: “standard”), which keeps water retention stable in warm mixing water and long pump lines. Viscosities are Brookfield RV, 2 % solution, 20 °C; NDJ-1 readings are about twice as high.
| Render | Cellulose ether (viscosity) | Starting dosage | Comment |
|---|---|---|---|
| Hand-applied base coat, 10–15 mm | K100 (45,000–60,000) / EM100 (45,000–60,000) | 0.12–0.20 % | Highest render-grade viscosity for body on the wall at low dosage |
| Machine-sprayed render | EM60 (30,000–40,000) · EM80 (35,000–45,000) / K75 (35,000–40,000) | 0.15–0.25 % | Medium viscosity passes the pump; combine with ST2109 or ST3152 starch ether |
| Finishing render / float coat, 3–5 mm | K75 / EM60 | 0.15–0.20 % | Easier floating, longer open time |
| One-coat (OC) exterior render | EM100H (45,000–60,000) | 0.20–0.30 % | Water retention “high” and sag resistance “excellent” for hot façades |
| Lightweight / thermal render | EM100H / K100 | 0.20–0.30 % | Holds light aggregate in suspension at the upper dosage |
| Renovation render | EM80 / EM100 | 0.15–0.20 % | Combine with air entrainer, no hydrophobic film |
Accurate® redispersible polymer powder — not every render needs polymer; use it where adhesion or flexibility is declared. All four grades below list renders or plasters on their technical data sheets.
| Render | Grade (TDS Tg / MFFT) | Dosage |
|---|---|---|
| Base coat on concrete, AAC, mixed substrates | Rigid 4012N or 5011N (Tg 10 ± 5 °C / 4 °C) | 1–2 % |
| Exterior OC render, high-stress areas (plinths, parapets) | Semi-flexible 4025N (Tg 0 °C / 1 °C) | 2–3 % |
| Render over insulation or old render | Flexible 5045N (Tg −10 ± 5 °C / 0 °C) | 3–4 % |
| Water-repellent render (W2) | Strong hydrophobic 8035H (TDS: mineral renders & plasters; Tg −10 ± 5 °C / 0 °C) | 2–3 % |
NOVASTAR® specialty additives
Dosages are percentages of the total dry mix as laboratory starting points; the technical data sheets do not prescribe dosages.
| Symptom | Likely cause | Adjustment |
|---|---|---|
| Render sags or slumps on the wall at 15 mm | Viscosity too low; too much water; no thixotropy | EM100H (sag resistance “excellent”); 0.03 % ST2109; reduce water 1 % |
| Map cracking within 24 h | Plastic shrinkage from fast water loss | EM100H for water retention; 0.1 % PP fibre; protect from sun and wind |
| Later shrinkage cracks, 1–4 weeks | Too much binder or water; no flexibility | Lower cement content, add 2–3 % 4025N, cure |
| Hollow sound, debonding from concrete | Dense substrate, no key, no polymer | Spatterdash or bonding coat; 2 % 5011N; wet the substrate |
| Debonding from AAC blocks | Substrate sucked the water | K100 / EM100 at 0.20 %; pre-wet or prime the blocks |
| Pump blockage, surging | Water retention collapses under pressure; air | EM80 / EM100 (heat resistance “excellent”); ST3152; P805 defoamer; constant water dosing |
| Dusting, weak surface | Water retention too low; over-floating | Raise cellulose ether 0.03 %; 1 % 4012N |
| Efflorescence, white bloom | Water migration carrying lime and salts | SHP 0.3 %; hydrophobic 8035H; low-alkali cement |
| Render stays damp, algae | Capillary uptake | SHP 0.3–0.5 %; W2 class design |
Related reading: Machine-applied render: pump blockage and sagging · Water retention in dry-mix mortar · Crack resistance in dry-mix mortar.
| Factor | Hand-applied | Machine-sprayed |
|---|---|---|
| Viscosity | High (K100 / EM100) for body on the trowel | Medium (K75 / EM60–EM80) to pass the pump and hose |
| Water retention | Important on absorbent substrates | Critical — pressure and shear squeeze water out of the mortar |
| Thixotropy | Helpful (ST1506-A) | Essential: ST2109 or ST3152 at 0.02–0.06 % so the mortar stiffens on impact with the wall |
| Air content | 8–15 % | 12–20 %, controlled with defoamer to avoid strength loss |
| Cellulose ether type | HPMC or HEMC | HEMC preferred: heat resistance “excellent” on the TDS, lubrication in the hose |
| Component | Machine-sprayed base render | One-coat exterior render (OC) |
|---|---|---|
| CEM II/B 32.5 or 42.5 | 18–22 % | 20–24 % |
| Hydrated lime | 3–5 % | 2–4 % |
| Sand 0–2 mm | 70–75 % | 65–70 % |
| Limestone filler / lightweight filler | 3–5 % | 5–8 % |
| Landercoll® HEMC | EM80 0.18 % | EM100H 0.25 % |
| NOVASTAR® starch ether | ST3152 0.03 % | ST2109 0.03 % |
| Accurate® RDP | — | 4025N 2 % |
| NOVASTAR® SHP75 / SHP80 | — | 0.3 % |
| PP fibre 6 mm | — | 0.1 % |
| Air-entraining agent | 0.01–0.03 % | 0.01–0.03 % |
| Pigment | — | as required |
Starting points only; adjust to local sand grading and the declared EN 998-1 class.
Render is a high-volume, low-dosage product, so additive cost per tonne of mortar is small but consistency is everything: a viscosity swing of 15 % in the cellulose ether changes water demand on the pump. LANDU manufactures Landercoll® cellulose ethers in its own three plants in Shandong (75,000 t/year total capacity) under ISO 9001 with batch viscosity certificates, supplies REACH-compliant grades to dry-mortar producers in more than 60 countries, and holds stock with partners in several European countries, including Greece, Spain and Italy. Factory lead time 7–15 working days; 25 kg bags on 500 or 600 kg pallets (10 t per 20′, 22 t per 40′ container); MOQ 1 t for cellulose ether; shelf life two years for K75, K100, EM80 and EM100.
Start at 0.18–0.20 % of the dry mix with Landercoll® EM80 (HEMC) or K75, plus 0.03 % ST3152 starch ether. Adjust in 0.02 % steps: too little shows as pump surging and dusting, too much as a sticky surface that is hard to float.
Not always. Interior and standard exterior base coats on brick rarely need polymer. Add 1–2 % rigid 4012N or 5011N on dense concrete or AAC, 2–3 % semi-flexible 4025N for one-coat and high-stress zones, and 3–4 % flexible 5045N when rendering over insulation or old render.
0.2–0.5 % NOVASTAR® SHP silicone hydrophobic powder, optionally with the strongly hydrophobic RDP 8035H, gives c ≤ 0.2 kg/m²·min^0.5 in most GP and OC renders while keeping the render vapour-open.
Either works; HEMC (Landercoll® EM60, EM80, EM100, EM100H) is usually chosen for machine application and hot climates because the TDS rates its heat resistance "excellent" and it lubricates the hose better. HPMC (K75, K100) is the cost-effective choice for hand-applied interior render.
AAC absorbs water much faster, so the render dries from the back before it hydrates. Move to EM100H at 0.20–0.25 % (water retention "high"), pre-wet or prime the blocks, and add 0.1 % PP fibre.
Yes. Landercoll® cellulose ethers and Accurate® RDP are white to off-white powders and do not affect pigment shade; SHP reduces the water movement that causes colour patchiness and efflorescence on coloured OC renders.
We return a grade recommendation and starting dosage within two working days and ship samples free of charge.
LANDU — Committed to Every Gram.