# Waterproof Mortar Additives: RDP, SHP, HPMC

Waterproof Mortar Additives for Rigid and Flexible Cementitious Waterproofing

Hydrophobic and flexible additives for waterproof mortars, slurries and coatings.

Divider

LANDU: Your Waterproof Mortar Additives Manufacturer

Divider

Cement is not waterproof; a dense, polymer-modified, hydrophobic cement mortar is. Three additives do that work: a redispersible polymer powder that fills capillaries and bridges cracks, a silicone hydrophobic powder that stops water being drawn in, and a cellulose ether that keeps the thin layer workable long enough to cure properly. A defoamer closes the last pores. This page gives the Accurate®, NOVASTAR® and Landercoll® grades for rigid waterproof mortars, one-component flexible slurries and waterproof renders, with starting dosages and a defect table.

Three waterproofing systems

Divider

| System | Build-up | Reference requirements | Additive priorities |
| --- | --- | --- | --- |
| Rigid polymer-modified waterproof mortar | 2–5 mm trowel or brush, 2 coats | EN 1504-2 coating / national specs: impermeability ≥ 0.8–1.5 MPa, adhesion ≥ 1.0 N/mm², capillary absorption w ≤ 0.1 kg/m²·h^0.5 | Hydrophobicity, density, adhesion, workability |
| One-component flexible waterproofing slurry (powder) | 1.5–3 mm, 2 coats under tiles, on balconies, in wet rooms | EN 14891 CM (± O/P/S): watertightness at 1.5 bar, crack bridging ≥ 0.75 mm at 23 °C, adhesion ≥ 0.5 N/mm² initial, after water, heat, freeze–thaw | High polymer content, flexibility, adhesion to concrete and tile adhesive |
| Waterproof render / plaster | 10–15 mm render for basements, tanks, plinths | EN 998-1 W2, impermeability | Water retention, hydrophobicity, crack control, sulphate-resistant binder |

Grade selection

Divider

**Accurate® redispersible polymer powder** — the main waterproofing additive. The hydrophobic grades are graded on their technical data sheets: 8032H "medium hydrophobic effect", 8035H "strong hydrophobic effect", 8048H "very strong hydrophobic" and instant-dissolving (disperses within about 20 seconds); 9028E and 9055E are acrylic–silane powders with a hydrophobic, weather-resistant film and a "lotus-leaf" anti-soiling surface.

| System | Grade (TDS positioning, Tg / MFFT) | Dosage | Role |
| --- | --- | --- | --- |
| Rigid waterproof mortar | 8048H (TDS: waterproof mortar / putty / coating; MFFT 0 °C) or 8032H (TDS: waterproof mortars; Tg −10 ± 5 °C / 0 °C) | 2–4 % | Capillary blocking plus water repellency in one component |
| Rigid waterproof mortar, economy | Rigid 5011N (Tg 10 ± 5 °C / 4 °C) + SHP | 2–3 % | Density and adhesion; SHP supplies the repellency |
| One-component flexible slurry | Flexible 5045N (Tg −10 ± 5 °C / 0 °C) or acrylic–silane 9055E (Tg −15 °C / 0 °C; TDS: polymer waterproof mortars, waterproof slurries) | 15–30 % | Crack bridging ≥ 0.75 mm (CM) and adhesion after water and freeze–thaw |
| Flexible slurry, high crack bridging (CM O1/O2) | 9055E or 5045N + 8048H blend | 25–35 % | Crack bridging at low temperature; hydrophobic component for long-term watertightness |
| Waterproof render | Strong hydrophobic 8035H (TDS: mineral renders & plasters) or semi-flexible 4025N (Tg 0 °C / 1 °C) | 1–3 % | Adhesion and reduced permeability |

**NOVASTAR® specialty additives**

| Additive | Grades | Dosage | Role |
| --- | --- | --- | --- |
| Silicone hydrophobic powder | SHP75 / SHP80 (silane/resin active; bulk density 400–600 g/L; pH 7–9) | 0.2–0.5 % (TDS range 0.1–0.5 %) | Prevents liquid water transport through the cured mortar by surface or capillary action, reduces 24 h water absorption and efflorescence, UV-stable, limited impact on mechanical properties |
| PCE superplasticizer | 540P (recommended for waterproof mortar; water-reduction rate 34 % on the product page) or 580P; TDS-series 590P (powder, water reduction ≥ 25 %, 97 % solids, chloride ≤ 0.02 %) | 0.1–0.3 % | Lower w/c → denser matrix, higher impermeability |
| Powder defoamer | P805 standard; P806 alkali-resistant; P807 low-temperature | 0.1–0.3 % | Closes pinholes and air pores, essential with high polymer |
| PP fibre | 3–6 mm | 0.05–0.15 % | Crack control in rigid mortars and renders |

**Landercoll® cellulose ether** (Brookfield RV, 2 %, 20 °C)

| System | Grade | Dosage |
| --- | --- | --- |
| Rigid waterproof mortar, brush / trowel | K100 (45,000–60,000 mPa·s) / EM100 (45,000–60,000) or EM100H | 0.15–0.30 % |
| One-component flexible slurry | K40 (18,000–20,000) / EM40HT (18,000–23,000) | 0.10–0.20 % — low enough to keep the slurry brushable |
| Waterproof render | K100 / EM100 · EM100H (water retention "high", sag resistance "excellent") | 0.15–0.25 % |

Dosages are percentages of the total dry mix for laboratory starting points; the technical data sheets do not prescribe dosages. Flexible slurries are polymer-dominated and their cellulose ether dosage is kept low.

How the additives work together

Divider

- **Polymer powder** redisperses in the mixing water and, as the mortar dries, forms a continuous film in the pores and at the interface. At 2–4 % it reduces permeability and improves bond; at 15 % and above the film becomes a continuous elastic matrix that bridges cracks. The 8032H TDS notes that at common dosages it does not change water-vapour transmission or rheology — the mortar stays vapour-open.
- **Silicone hydrophobic powder** coats the pore walls so that water cannot be drawn in by capillarity, but vapour can still leave. It is the additive that keeps a waterproof render dry-looking and stops efflorescence.
- **Cellulose ether** holds water in a 2–3 mm layer on an absorbent substrate until the cement has hydrated and the polymer film has formed; without it, thin waterproof coats dry out and powder.
- **Defoamer** removes the air that polymer powder and brushing introduce; each entrapped bubble is a potential leak path in a 2 mm coat.
- **PCE** lowers water demand and so the capillary porosity of rigid systems.

Troubleshooting

Divider

| Symptom | Likely cause | Adjustment |
| --- | --- | --- |
| Damp patches or seepage after curing | Capillary porosity; no hydrophobic component | SHP 0.3 %; hydrophobic RDP 8048H; 540P or 590P to cut water |
| Cracks in rigid coat after drying | Shrinkage, fast drying, thick coat | Two coats ≤ 2 mm; K100 0.25 %; 2–3 % RDP; 0.1 % fibre |
| Flexible slurry fails crack bridging | Polymer below 15 %; rigid grade used | 5045N / 9055E ≥ 20 %; check film-forming temperature (MFFT 0 °C for both) |
| Debonding from damp concrete | Substrate not saturated surface-dry; low polymer | Pre-wet to SSD; RDP ≥ 3 %; brush first coat into surface |
| Pinholes in the coat | Air from mixing and brushing | P805 0.2–0.3 %; slow mixer; second coat crosswise |
| Powdering of thin coat | Water lost to substrate before hydration | K100 / EM100H at 0.25–0.30 %; pre-wet; avoid sun |
| Efflorescence on waterproof render | Water movement through render | SHP 0.3–0.5 %; hydrophobic 8035H; W2 design |
| Tile adhesive will not bond to the slurry | Slurry surface too smooth or dusty; wrong polymer | Use 5045N-type with good re-wettability; follow EN 14891 adhesion test |
| Slurry stiffens in the bucket | Cellulose ether too high for a brush product | Drop to K40 / EM40HT at 0.10–0.15 % |
| Lumps when the powder is mixed with water on site | Polymer redispersion too slow for hand mixing | 8048H (instant-dissolving, ≈ 20 s) or allow a 5-minute maturing rest and remix |

Starting formulations (dry mix, laboratory basis)

Divider

| Component | Rigid waterproof mortar | One-component flexible slurry (CM) |
| --- | --- | --- |
| CEM I 42.5 (sulphate-resistant where required) | 35–40 % | 30–35 % |
| Quartz sand 0.1–0.5 mm | 50–55 % | 35–40 % |
| Limestone filler | 5–8 % | 5–10 % |
| Accurate® RDP | 8048H 3 % | 5045N 22 % |
| NOVASTAR® SHP75 / SHP80 | 0.3 % | — (optional 0.2 %) |
| Landercoll® cellulose ether | K100 0.25 % | K40 0.15 % |
| NOVASTAR® PCE 540P / 590P | 0.2 % | 0.1 % |
| NOVASTAR® defoamer P805 | 0.2 % | 0.3 % |
| PP fibre 3 mm | 0.1 % | — |
| Calcium formate / accelerator | 0.3–0.5 % | — |
| Water | ≈ 20–23 % | ≈ 24–28 % |

Starting points only; EN 14891 watertightness and crack-bridging tests must be run on the final blend.

Products referenced on this page

Divider

- [Accurate® RDP for waterproof mortar](https://landuchina.eu/products-and-solutions/rdp-for-waterproof-mortar/) · [Accurate® RDP range (rigid, flexible, hydrophobic, acrylic–silane)](https://landuchina.eu/products-and-solutions/china-rdp-powder-supplier-landu-accurate-high-performance-customizable-solutions/)
- [NOVASTAR® SHP silicone hydrophobic powder](https://landuchina.eu/products-and-solutions/novastar-specialty-additives/novastar-shp-the-ultimate-silicone-hydrophobic-powder-for-building-protection/) · [SHP and capillary water absorption](https://landuchina.eu/silicone-hydrophobic-powder-capillary-water-absorption/)
- Landercoll® HPMC for waterproof mortar · Landercoll® HEMC for waterproof mortar
- [NOVASTAR® PCE powder for waterproof mortar](https://landuchina.eu/products-and-solutions/pce-powder-for-waterproof-mortar/) · [PCE 540P](https://landuchina.eu/pce-540p/) · [Powder defoamer](https://landuchina.eu/products-and-solutions/powder-defoamer/) · [PP fibre](https://landuchina.eu/products-and-solutions/polypropylene-fiber/)

Supply

Divider

Waterproofing products carry the highest polymer dosages in dry-mix, so RDP quality — redispersibility, film formation, anti-caking — decides the product. LANDU produces Accurate® polymer powders, Landercoll® cellulose ethers and NOVASTAR® SHP, PCE and defoamers in-house: three production bases in Shandong, 75,000 t/year, ISO 9001, REACH-compliant portfolio. European stock through partners in several countries, including Greece, Spain and Italy; factory lead time 7–15 working days; MOQ 500 kg for RDP. Per TDS, RDP ships in 25 kg bags on 600 / 700 / 1,300 kg pallets (13 t per 20', 26 t per 40'), shelf life one year with use within six months recommended; single-stacked pallets only, because the powder is thermoplastic.

Waterproof Mortar Additives: Frequently Asked Questions

Divider

Answers on additive selection, testing, samples and supplier qualification.

How to Change my Photo from Admin Dashboard?

Far far away, behind the word mountains, far from the countries Vokalia and Consonantia, there live the blind texts. Separated they live in Bookmarksgrove right at the coast

Request Samples and a Grade Recommendation

Divider

Tell us the system (rigid mortar, flexible slurry or render), the substrate and the standard you declare.

We return RDP, SHP and cellulose ether grades with dosages within two working days and ship samples free of charge.

REQUEST SAMPLES