title: "Grouting Mortar Additives for Cement-Based Grout"
url: https://landuchina.eu/grouting-mortar-additives/
description: "Non-shrink, pumpable, anchoring and tile grout additives: NOVASTAR® PCE 530P and defoamer P805, Landercoll® HPMC/HEMC, Accurate® RDP for flow and bleed control."
author: "LANDU Laboratory Team"
date_published: 2026-05-23T07:38:54+00:00
date_modified: 2026-11-18T13:13:25+00:00
language: en-US
type: page
generator: LemonX AEO 1.4.12
---

# Grouting Mortar Additives for Cement-Based Grout

Grouting Mortar Additives: Flow Retention, Volume Stability, Bleed Control

Divider

Flow, bleed control and early strength for non-shrink, injection, anchoring and tile grouts.

LANDU: Your Grouting Mortar Additives Manufacturer

Divider

Grout is the one mortar that must flow into a space it cannot be pushed into — under a machine base plate, around an anchor bar, into a 3 mm tile joint — and then stay there without bleeding, shrinking or cracking. That behaviour comes from a tightly balanced additive package: a superplasticizer for flow at low water, a trace of cellulose ether to keep the mix cohesive, a defoamer to release pumped-in air, polymer for bond and ductility, and an expansion component for volume stability. This page gives the NOVASTAR®, Landercoll® and Accurate® grades for each grout type, with starting dosages and a troubleshooting table.

Four grout types, four briefs

Divider

| Grout type | Where used | Reference requirements | Additive priorities |
| --- | --- | --- | --- |
| Non-shrink precision grout | Machine bases, bearing plates, column bases, precast joints | National specs / EN 1504-6 anchoring: flow 250–300 mm (cone), 1-d strength ≥ 20 MPa, 28-d ≥ 60 MPa, expansion 0–0.3 % at 24 h, no bleeding | High water reduction, bleed control, controlled plastic expansion, air control |
| Pumpable / injection grout | Post-tensioning ducts, voids, masonry consolidation | Marsh-cone flow 20–30 s, bleeding < 0.3 %, volume change ≤ +0.1 / −0.1 % | Flow retention over 60–90 min, anti-washout cohesion, zero bleeding |
| Anchoring grout | Rebar, bolts and rock bolts in drilled holes | EN 1504-6: pull-out displacement ≤ 0.6 mm at 75 kN; early strength | Thixotropy for overhead holes, fast strength, low shrinkage |
| Tile joint grout | Ceramic and stone joints 2–15 mm | EN 13888: CG1 / CG2 (W = reduced water absorption, A = high abrasion resistance) | Workability and clean-off, flexibility, water repellency, colour stability |

Grade selection

Divider

| Additive | Grades (TDS data) | Non-shrink precision grout | Pumpable / injection grout | Anchoring grout | Tile joint grout (CG2 WA) |
| --- | --- | --- | --- | --- | --- |
| NOVASTAR® PCE, 530P–580P series (product-page data) | 530P (Portland-cement system, water-reduction rate 34 %) and 550P are recommended for grouting and injection mortar; 540P (sulfoaluminate cement, 34 %) is compatible and suits rapid-setting and pressure grouts; 580P (37 %) is designed for high-strength non-shrink, sleeve and wind-turbine grouts | 530P or 580P 0.3–0.6 % | 530P + 550P 0.3–0.5 % | 540P or 580P 0.2–0.4 % | — |
| NOVASTAR® PCE superplasticizer (TDS series) | 590P — high water reduction (≥ 25 %, 97 % solids, chloride ≤ 0.02 %); 600P — long-lasting slump retention; 590FP — early strength (12 h strength ratio > 240 %, setting shortened > 1 h). TDS dosage 0.1–0.5 % of cementitious material | 590P 0.3–0.6 % of dry mix | 590P + 600P 0.3–0.5 % (600P share rises with placement time) | 590FP 0.2–0.4 % | — or 590P 0.05–0.1 % |
| NOVASTAR® powder defoamer | P805 standard; P806 alkali-resistant; P807 low-temperature | P805 / P806 0.1–0.3 % | 0.1–0.2 % | 0.1–0.2 % | 0.05–0.1 % |
| Landercoll® cellulose ether | K04 (300–500 mPa·s; self-leveling grade), K40 (18,000–20,000 mPa·s; TDS: crack filler / tile grout, masonry mortar), MPE4090-T (35,000–45,000 mPa·s; TDS: crack filler / tile grout, tile adhesive), EM40HT (18,000–23,000 mPa·s; TDS: repair mortar, tile adhesive) | K04 0.02–0.04 % (cohesion without flow loss) | K04 / K40 0.03–0.06 % (anti-washout) | EM40HT 0.10–0.20 % (thixotropy, excellent water retention) | K40 or MPE4090-T 0.15–0.30 % |
| Accurate® RDP | 4012N, 5011N rigid (Tg 10 ± 5 °C); 4025N semi-flexible (Tg 0 °C); 5045N flexible (Tg −10 ± 5 °C); 8032H medium hydrophobic, 8035H strong hydrophobic (TDS: tile grouts); 9028E / 9055E acrylic–silane (TDS: cement-based grouts, anti-soiling) | 5011N 1–2 % (bond, ductility) | — or 5011N 1 % | 4012N / 5011N 1–2 % | 5045N or 4025N 2–4 % + 8035H / 9055E for W class |
| NOVASTAR® SHP hydrophobic powder | SHP75 / SHP80 (TDS: grouts and joint fillers; dosage 0.1–0.5 %) | — | — | — | 0.2–0.5 % (W class, stain resistance) |
| NOVASTAR® starch ether | ST3152 (machine-applied mortars, thixotropy), ST3547 (universal, low ash) | — | — | ST3152 0.02–0.05 % (overhead holes) | ST3547 0.02–0.05 % (creamy clean-off) |
| PP fibre | 3–6 mm | 0.05–0.1 % | — | 0.05–0.1 % | — |
| Expansion component (third-party) | Plastic-phase (Al-powder based) and/or hardened-phase (CSA / CaO) expansive agent | as required for 0–0.3 % | as required | as required | — |

Dosages are percentages of the total dry mix for laboratory starting points; the technical data sheets do not prescribe mortar dosages. In high-flow grouts cellulose ether is dosed in hundredths of a percent; use K04 and adjust in 0.005 % steps. PCE powders must not be combined with naphthalene sulfonate superplasticizers, and compatibility with other admixtures has to be tested (TDS).

Troubleshooting

Divider

| Symptom | Likely cause | Adjustment |
| --- | --- | --- |
| Water film on top after 15 min (bleeding) | No cohesion component; PCE overdosed | Add 0.01–0.02 % K04; cut 590P by 0.05 %; check sand fines |
| Flow drops from 280 to 220 mm within 30 min | Cement–PCE incompatibility; heat; C₃A-rich cement | Replace part of 590P with 600P (slump retention); cool water; test second cement |
| Pinholes and foam on surface, low density | Entrained air not released | P805 0.2–0.3 % (P806 in cement-rich, high-pH grouts); slower mixing |
| Shrinkage cracks after demoulding | No expansion component; high water | Plastic-phase expander; lower w/b with 590P; cure 3 days wet |
| Grout expands too much, cracks the edge | Over-dosed expander, high temperature | Reduce expander; test expansion at site temperature |
| Pump line blocks, surging | Segregation under pressure; air | K04 0.03 %; P805; constant water dosing; avoid sand > 2 mm |
| Low 1-day strength | High w/b; retardation from overdosed PCE or cellulose ether | 590FP (early-strength PCE) at correct dose; K04 only; P807 and warm water if cold |
| Tile grout cracks or shrinks in wide joints | Low polymer, fast drying | 5045N 3 %; MPE4090-T 0.2 %; fine sand 0–0.5 mm; wet cure |
| Tile grout stains, absorbs water | No hydrophobic component | SHP 0.3 %; hydrophobic RDP 8035H or acrylic–silane 9055E (TDS: lotus effect, anti-soiling) |
| Patchy colour in pigmented grout | Efflorescence and uneven water | SHP; consistent water dosing; low-alkali white cement |

Starting formulations (dry mix, laboratory basis)

Divider

| Component | Non-shrink precision grout | CG2 WA tile grout |
| --- | --- | --- |
| CEM I 52.5 R | 40–45 % | White cement 42.5: 30–35 % |
| Silica fume / fly ash | 3–5 % | — |
| Quartz sand 0–2 mm (grout) / 0–0.3 mm (tile grout) | 48–52 % | 55–60 % |
| Limestone filler | — | 5–8 % |
| NOVASTAR® PCE | 530P or 590P 0.4 % | 590P 0.05 % |
| NOVASTAR® defoamer P805 | 0.2 % | 0.05 % |
| Landercoll® cellulose ether | K04 0.03 % | MPE4090-T 0.20 % |
| Accurate® RDP | 5011N 1.5 % | 5045N 3 % |
| NOVASTAR® SHP75 / SHP80 | — | 0.3 % |
| Expansive agent (plastic-phase) | 0.01–0.03 % Al-based or per supplier | — |
| PP fibre 6 mm | 0.05 % | — |
| Pigment | — | as required |

Starting points only; expansion and early strength must be verified at the temperatures the grout will be placed at.

Products referenced on this page

Divider

- [NOVASTAR® PCE range](https://landuchina.eu/products-and-solutions/polycarboxylate-superplasticizer-pce/) · [PCE 530P](https://landuchina.eu/products-and-solutions/economical-novastar-pce-530p/) · [PCE 540P](https://landuchina.eu/pce-540p/) · [PCE 580P](https://landuchina.eu/products-and-solutions/novastar-pce-580p/) · [PCE 590P](https://landuchina.eu/products-and-solutions/novastar-specialty-additives/polycarboxylate-superplasticizer-pce-high-performance-concrete-additive/novastar-pce-flake-590p/)
- [NOVASTAR® powder defoamer](https://landuchina.eu/products-and-solutions/powder-defoamer/) — P805 / P806 / P807
- [Landercoll® HPMC range](https://landuchina.eu/products-and-solutions/hydroxypropyl-methylcellulose-manufacturer/) — K04, K40, MPE4090-T · [Landercoll® MHEC / HEMC range](https://landuchina.eu/mhec-hydroxyethyl-methyl-cellulose/) — EM40HT
- [Accurate® RDP](https://landuchina.eu/products-and-solutions/china-rdp-powder-supplier-landu-accurate-high-performance-customizable-solutions/)
- [NOVASTAR® SHP](https://landuchina.eu/products-and-solutions/novastar-specialty-additives/novastar-shp-the-ultimate-silicone-hydrophobic-powder-for-building-protection/) · [HPS starch ether](https://landuchina.eu/products-and-solutions/hydroxypropyl-starch-ether-hps/) · [PP fibre](https://landuchina.eu/products-and-solutions/polypropylene-fiber/)
- Related: [Repair mortar additives](https://landuchina.eu/applications/repair-mortar/) · [Self-leveling compound additives](https://landuchina.eu/self-leveling-compound-additives/)

Supply

Divider

Grout formulations run at very low cellulose ether and very high superplasticizer dosages, so both must be consistent lot to lot. LANDU manufactures Landercoll® cellulose ethers, Accurate® RDP and NOVASTAR® PCE and defoamers in its own plants in Shandong (three production bases, 75,000 t/year) under ISO 9001, supplies REACH-compliant grades to more than 60 countries and holds European stock with partners in several countries, including Greece, Spain and Italy. Factory lead time 7–15 working days. Packaging per TDS: PCE powder in 25 kg woven bags with PE liner (shelf life 12 months, use within 60 days of opening); cellulose ether and RDP in 25 kg bags on pallets.

Grouting Mortar Additives: Frequently Asked Questions

Divider

Answers on additive selection, testing, samples and supplier qualification.

How to Change my Photo from Admin Dashboard?

Far far away, behind the word mountains, far from the countries Vokalia and Consonantia, there live the blind texts. Separated they live in Bookmarksgrove right at the coast

Request Samples and a Grade Recommendation

Divider

Send your grout type, target flow and strength schedule.

We return a PCE, defoamer, cellulose ether and polymer recommendation within two working days and ship samples free of charge.

REQUEST SAMPLES

**[Ask a Formulation Engineer](https://landuchina.eu/contact-us/)**

*LANDU — Committed to Every Gram.*